PRODUCTS

DC- DC CONVERTER (CVCC400W TO 800 W) (Adjustable voltage / current )

FEATURES

  • APPLICATION USED IN MEDICAL EQUIPMENT, COMPUTER CONTROL SYSTEM & NETWORK, INDUSTRIAL AUTOMOTIVE AND TELECOMMUNICATION, DEFENCE & RAILWAYS EQUIPMENT.
  • Proven Technology CVCC-PWM Control.
  • Latest mosfet technology for switching.
  • Very Compact Size/ Light Weight , Wide Input Range
  • Highly efficient /Cost effective / Easy to connect.
  • Guaranteed input to output isolation.
  • CVCC Characteristic for Battery Charging, motor drive application, halogen lamp and inductive load application.
  • Internally program , external control or adjustable output voltage and current as per requirement.
  • Output.Voltage adjustment is available from 0 to max.
  • Output current adjustment is available from 10% to max.
  • Logic switch for output ON/OFF
  • Master slave operation with equal voltage and current sharing.
  • High power charger system configuration with stack able multiple unit.
  • No possiblility of unit to shut down as we have used multiple units to support total output
  • Inbuilt battery blocking diode (feature for battery charging application.)
  • Inbuilt battery reverse polarity protection (feature for battery charging application.)
  • All double rated component used in product for reliability and long life.

SPECIAL FEATURES

  • Soft start on DC side.
  • Class-F insulation for all magnetic.
  • Automatic voltage regulation using digital control logic.
  • Filter circuit to limit ripple.

TECHNICAL DATASHEET (Specification)

INPUT
DC Input range
:
9V-18V or 18V-36V or 36V- 63V or 63V-90V or 90V- 150V DC.150V -300V DC .(any one or as per your requirement)
Hold up time
:
20 m Sec @ Minimum input
Input Protection
:
Internal DC Fuse + Soft Start.
OUTPUT
Voltage
:
0V to260V DC Max. as per your requirement , fixed , veriable or programmable.
Current
:
10% to max.(100A) as per your requirement fixed , veriable. Or programmable.(Constant current type.)
O/P power
:
800W. Max.
Regulation
:
± 0.5% Line and Load.
Output ripple and noise
:
Less than 1% PK-PK.
Protection
:
O/P over voltage, over load & short circuit.
Indication
:
Two Nos. high quality digital panel meter to display output voltage and current .
Isolation
:
Between input & output up-to 2KV.
Working Temperature
:
(-)15° C to (+)85°C + ambient temperature.
Efficiency
:
Better than 70%.
Quality & Safety
:
to suit IEC 950 ,UL 1950.
Enclosure
:
MS powder coated 3U height enclosure with enclosure Table top and rack mounting facility.
Cooling
:
Natural heat sink & Fan provided for cooling.
Switch
:
Logic switch for output ON/OFF purpose.
Note
:
All Spacification are Subject To change without Notice.

TECHNICAL SPECIFICATIONS

MECHANICAL
  • L x D x H (mm) : 430 x 360x 133mm (3U) (enclosure dimension with DPM model)
  • L x D x H (mm) : 430 x 270x 133mm (3U) (enclosure dimension without DPM model)

Note : Send your enquiry with available input voltage range and required output voltage and current.